Artículos
Título:
Self-Assembled Multilayers of Water Soluble Modified-Chitosan And Glucose Oxidase For Detection Of Glucose In Milk Samples
Autor/es:
GULOTTA, FLORENCIA A.; DIAZ VERGARA, LADISLAO; MONTENEGRO, MARIANA;FERREYRA NANCY F.,*, PAZ ZANINI, VERÓNICA I
Revista:
SOUTHERN JOURNAL OF SCIENCES
Editorial:
SOUTHERN JOURNAL OF SCIENCES
Referencias:
Año: 2022 vol. 30 p. 1 - 1
Resumen:
ackground: A crucial aspect of electrochemical enzymatic biosensor development is the immobilization of the enzymes as it directly influences the sensitivity of the bioelectrode. Among the different methods used for the incorporation of enzymes on the surface of the transducers, layer-by-layer (LbL) self-assembly based on electrostatic interaction with polyelectrolytes of opposite charge stands out due to its simplicity and reproducibility. Aims: The aim of the work was to develop an electrochemical glucose biosensor by LbL assembly of a new functionalized chitosan polycation and the enzyme glucose oxidase (GOx). Methods: Chitosan was chemically functionalized with glucose by the Maillard reaction. The resulting polycation, named G-Chit, is soluble in the medium compatible with the enzyme. The bioelectrode was obtained by alternating adsorption of G-Chit and GOx onto carbon paste electrodes. By selecting the number of bilayer of G-Chit/GOX, the enzyme concentration and the pH, we opti